YUW1-2000/3P Drawer Air Circuit Breaker
YUW1-2000/3P Drawer Air Circuit Breaker
YUW1-2000/3P Fixed Air Circuit Breaker

YUW1 Series 200A-6300A Air Circuit Breaker universal circuit breaker drawer and fixed ACB 3P/4P

UW1 series Air Circuit Breaker(hereinafter referred to as circuit breaker) is applied in distribution network with AC 50HZ ,rated voltage 690V(or below),and rated current 200A-6300A.

Get A Quote

It is used to distribute electric energy, protect circuit and power supply from damage of defaults,such as overload,under voltage,short circuit,single-phase grounding.Circuit breaker has intelligent protection function,and its selective protection is accurate.

 

Pole: 3P,4P 

Rated current: 1000A, 2000A, 3200A, 4000A, 6300A

Ue: AC 380V/400V/600V/690V; Ui: 1000V; Uimp: 12kV;

In: 200A, 400A, 630A, 800A, 1000A, 1250A, 1600A;

Type of overcurrent trip: Electronic;

AC 400V: Ics=55kA; Icu=50kA/1s;

AC 480V: Ics=65kA; Icu=85kA/1s;

AC 690V: Ics=42kA; Icu=50kA; Icw=42kA/is;

Selective category: Category B; intended for isolation.

Product standards and technical requirements : GB/T 14048.2-2020.

Name Details
Product category Universal Type Circuit Breaker
Design code 1
Current rank (Amp) 1000A,2000A,3200A,4000A,6300A
Breaking capacity M=Standard,H=High breaking
Pole 3P,4P
Product structure C=Drawer type,G=Fix type
Controller L=Economy type,M=Intelligent,H=Communication type
Product Summary

 

YUW1 series Air Circuit Breaker(hereinafter referred to as circuit breaker) is applied in distribution network with AC 50HZ ,rated voltage 690V(or below),and rated current 200A-6300A. It is used to distribute electric energy, protect circuit and power supply from damage of defaults,such as overload,under voltage,short circuit,single-phase grounding.Circuit breaker has intelligent protection function,and its selective protection is accurate.Besides,it can improve the reliability of power supply and avoid unnecessary blackout.At the same time ,it possesses open-type communication interface to realize four-remote function,namely remote control,remote regulating,remote measurement and remote communication,in order to meet the requirement of control center and automatic system.This circuit breaker has isolation function.

 

 

Classify

 

1. Accord to install:Fix type,Drawer type.
2. Accord to pole:3P、4P
3. Accord to operation:Electric operation,Manual operation(Repair,maintenance)

 

 

Release

 

Intelligence controller,under-voltage instant(or delayed)release,shunt release.

 

 

Intelligence Controller Function

 

1. intelligence controller:H(intelligence type),M(Standard type)、L(Economy type)

 

2. Have overload long delayed inverse time limit,short delayed inverse time limit,constant time-lag and instant function,it can according to user require to set protect.

 

3. Single ground protect function.

 

4. Display function:setting current display,action current display and each line voltage main display(voltage display need ask us when give me the order)

 

5. Alarm function:overload alarm.

 

6. Self test function:overheating self test,microcomputer self diagnosis.

 

7. Test function:intelligent controller of operating characteristic.

 

 

Normal Use And Installation Condition

 

1. Ambient air temperature:upper limit value not exceeding+40℃,lower limiting value not exceeding -5℃,average value not exceeding +35℃.Special orders expected.

 

2. Install address of altitude not exceeding 2000m.

 

3. Atmospheric conditions:Atmosphere relative humidity not exceeding 50% when ambient air is +40℃,it can have higher of relative humidity in the lower temperature ,the average max relative humidity is 90% in the max wet month,this month average max temperature is +25℃ at the same time ,it need to think about condensation of product’s surface which will a[[ear with the change of temperature.It need consult with my company when it exceed regulated requirements.

 

4. Level of protection:IP30.

 

5 Class of pollution:3 class.

 

6. Use classes:B classes or A classes.

 

7. Installation category:Rated operating voltage 660V(690V) and below circuit breakers and undervoltage demerters,power transformer primary coil of installation category isⅣ,other assist circuit,controller installation category is Ⅲ.

 

8. Installation condition:Breaker need according to this instruction require to install,breaker of vertical gradient not exceeding 5°(mine breaker of vertical gradient not exceeding 15°)

Related Products

News information

One Two Three brand frame circuit breaker passed the national CQC certification

Frame circuit breaker (ACB)Frame circuit breaker is also called universal circuit breaker. All its parts are installed in an insulated metal frame, wh...

Happy Mid-Autumn Festival

The Mid-Autumn Festival is the traditional festival of the Chinese nation, here we One Two Three Electric Co., Ltd. wish everyone a happy Mid-Autumn F...

Automatic Transfer Switch is Used for Cooperative Operation Between Generator Sets

Automatic Transfer Switch is Used for Cooperative Operation Between Generator Sets

The method of turning off the ATS of double power supply in the operation of the generator set is divided into manual operation mode and automatic ope...

Cast First Class Automatic Transfer Switch Quality

Cast First Class Automatic Transfer Switch Quality

One Two Three Electric Co,.Ltd as the largest and most professional automatic transfer switch manufacturer in China, the quality of switch determines...

GET A QUOTE

Get in Touch

Captcha Code
×