General ■ YGLR Series fuse group of
isolation switch ( hereinafter short for switch) is multi-pole and manual operation switch, whose housing is made of glass fiber reinforced unsaturation polyester, it has merits of high dielectric property, guard capacity and reliable operation.
■ The operation mechanism, it is accelerate mechanism of spring energy s torage, in stantaneous release, it is also a mechanism that is instantaneous making and breaking multi-breakpoint contact. It is no related with the speed of operation handle, t hus, it e xtremely improves each electric performance and mechanical performance.
■ Fuse group of isolation switch can makes sure making and br eaking cir cuit with load, and it has r eliable over current or short-circuit breaking protection.
■ Obviously saw the breaking state.
■ With strong hot and humidity proofing.
■ Because the switch owns the merits of graceful appearance, novel, simple, small volume and complete function, it is best selection among the same products .
Model description
Note: don't note if the function in the box is not necessary.
F-NC or NO auxiliary contact,
S-NO+ NC S type auxiliary contact,
U- U type auxiliary contact.
Example for lecto type : rated current 160A, 3 poles,
side face operation in the cabinet
Mated with the spec of fuse link Rated current of fuse group of isolation switch A | Rated current of fuse link A | Size of fuse link |
63 | 10 20 30 40 50 63 | 00C |
160 | 63 80 100 125 160 | 0 |
250 | 160 | 0 |
200 250 | 1 |
400 | 300 315 400 | 2 |
630 | 400 500 630 | 3 |
1250 | 800 1000 1250 | 4 |
YGLR-63~1250A / I Type Fuse Group of Isolation Switch It makes sure making and breaking circuit with load, with reliable over-current and short-circuit breaki ng prote ction, a lso obviously saw the breaking state.Own two poles, three poles, four poles ( three poles+ switch neutral pole). The fuser can be divided into 23 sp ecs from 63A to 1250A.
Structure and operation mode ■ Direct operation on front face: the handle is installed on the front face of switch.
■ Direct operation on side face: the handle is installed on the right of switch ( it is noted separately if the handle is installed on theleft of switch).
■ Front face operation outside of cabinet: the handle is installed on the front face outside of the distribution cabinet door.
■ Side face operation outside of cabinet: the handle is installed on the right of distribution cabinet outside. ( it is noted separately if the handle is installed on the left)
YGLR-63~400A/I Outline and installation dimensions
Specification | Size of fuse | External Dimension and Installation Dimension |
A | B | D | E | F | H | H1 | I | J | K | L | M | P | R | T | ΦX | Y |
YGLR -63A/3 | 0~00C | 152 | 118 | 20~30 | 117 | | | | 159 | 145 | 106 | 5 | 62.5 | 32 | | | | |
YGLR -63A/4 | 0~00C | 184 | 118 | 20~30 | 117 | | | | 159 | 145 | 106 | 5 | 62.5 | 32 | | | | |
YGLR -160/3 | 0~00 | 164 | 162 | 28~30 | 126 | 44 | 108 | 53 | 141 | 189 | 127 | 5.4 | 67 | 36 | 20 | 2.5 | 8.5 | 19.5 |
YGLR -160/4 | 0~00 | 200 | 162 | 28~30 | 126 | 44 | 144 | 53 | 141 | 189 | 127 | 5.4 | 67 | 36 | 20 | 2.5 | 8.5 | 19.5 |
YGLR -250/3 | 1 | 236 | 195 | 28~30 | 146 | 65 | 180 | 75 | 185 | 251 | 162 | 6.2 | 90.5 | 60 | 32 | 2.5 | 11 | 19.5 |
YGLR -250/4 | 1 | 296 | 195 | 28~30 | 146 | 65 | 240 | 75 | 185 | 251 | 162 | 6.2 | 90.5 | 60 | 32 | 2.5 | 11 | 19.5 |
YGLR -400/3 | 2 | 278 | 205 | 28~30 | 149 | 65 | 192 | 75 | 200 | 260 | 172 | 7 | 121 | 66 | 50 | 3 | 11 | 20 |
YGLR -400/4 | 2 | 344 | 205 | 28~30 | 149 | 65 | 258 | 75 | 200 | 260 | 172 | 7 | 121 | 66 | 50 | 3 | 11 | 20 |
YGLR-400~630A/I Outline and installation dimensions
Specification | Size of fuse | External Dimension and Installation Dimension | | | | | | | | |
A | A1 | B | B1 | C | E | H | H1 | H2 | J | J2 | J1 | K | M | N | P | R | S | S1 | T | V | U | W | ΦL | Y |
YGLR -400A/3 | 2 | 414 | 285 | 238 | 115 | 307 | 221 | 190 | 71 | 79 | 210 | 70 | 65 | 180 | 32.5 | 162 | 65 | 32 | 35 | 43 | 5 | 40.5 | 208 | 39.5 | 7 | 69 |
YGLR -400A/4 | 2 | 474 | 345 | 238 | 115 | 307 | 221 | 255 | 71 | 79 | 210 | 70 | 65 | 180 | 32.5 | 162 | 65 | 32 | 35 | 43 | 5 | 24.5 | 208 | 39.5 | 7 | 69 |
YGLR -630A/3 | 3 | 470 | 345 | 300 | 150 | 348 | 268 | 235 | 85 | 85 | 250 | 100 | 76 | 250 | 38.5 | 162 | 80 | 50 | 50 | 50 | 7 | 45.5 | 260 | 44.5 | 9 | 74 |
YGLR -630A/4 | 3 | 550 | 425 | 300 | 150 | 348 | 268 | 315 | 85 | 85 | 250 | 100 | 76 | 250 | 38.5 | 162 | 80 | 50 | 50 | 50 | 7 | 34.5 | 260 | 44.5 | 9 | 74 |
Specification | Size of fuse | External Dimension and Installation Dimension | | | | | | | | |
A | A1 | B | B1 | E | H | H1 | H2 | J | J2 | J1 | K | M | N | P | R | S | S1 | T | V | U | W | ΦL | Y |
YGLR -400A/3 | 2 | 500 | 285 | 238 | 115 | 221 | 190 | 71 | 79 | 210 | 70 | 65 | 180 | 32.5 | 119 | 65 | 32 | 35 | 43 | 5 | 40.5 | 208 | 39.5 | 7 | 69 |
YGLR -400A/4 | 2 | 560 | 345 | 238 | 115 | 221 | 255 | 71 | 79 | 210 | 70 | 65 | 180 | 32.5 | 119 | 65 | 32 | 35 | 43 | 5 | 24.5 | 208 | 39.5 | 7 | 69 |
YGLR -630A/3 | 3 | 550 | 345 | 300 | 150 | 268 | 235 | 85 | 85 | 250 | 100 | 76 | 250 | 38.5 | 119 | 80 | 50 | 50 | 50 | 7 | 45.5 | 260 | 44.5 | 9 | 74 |
YGLR -630A/4 | 3 | 630 | 425 | 300 | 150 | 268 | 315 | 85 | 85 | 250 | 100 | 76 | 250 | 38.5 | 119 | 80 | 50 | 50 | 50 | 7 | 34.5 | 260 | 44.5 | 9 | 74 |
YGLR-1250A Outline and installation dimensions