YGLR-1250A Fuse Group Isolation Switch

Place of Origin: Zhejiang, China (Mainland)
Model Number: YGLR-1250A

YGLR Series fuse group of isolation switch ( hereinafter short for switch) is multi-pole and manual operation switch, whose housing is made of glass fiber reinforced unsaturation polyester, it has merits of high dielectric property, guard capacity and reliable operation.

Quantity:
General
■ YGLR Series fuse group of isolation switch ( hereinafter short for switch) is multi-pole and manual operation switch, whose housing is made of glass fiber reinforced unsaturation polyester, it has merits of high dielectric property, guard capacity and reliable operation.
■ The operation mechanism, it is accelerate mechanism of spring energy s torage, in stantaneous release, it is also a mechanism that is instantaneous making and breaking multi-breakpoint contact. It is no related with the speed of operation handle, t hus, it e xtremely improves each electric performance and mechanical performance.
■ Fuse group of isolation switch can makes sure making and br eaking cir cuit with load, and it has r eliable over current or short-circuit breaking protection.
■ Obviously saw the breaking state.
■ With strong hot and humidity proofing.
■ Because the switch owns the merits of graceful appearance, novel, simple, small volume and complete function, it is best selection among the same products .

Model description
YGLR Series fuse group of isolation switch-1
Note: don't note if the function in the box is not necessary.
F-NC or NO auxiliary contact,
S-NO+ NC S type auxiliary contact,
U- U type auxiliary contact.
Example for lecto type : rated current 160A, 3 poles,
side face operation in the cabinet

Mated with the spec of fuse link
Rated current of fuse group of isolation switch A Rated current of fuse link A Size of fuse link
63  10 20 30 40 50 63  00C
160 63 80 100 125 160 0
250 160 0
200 250 1
400 300 315 400 2
630 400 500 630 3
1250 800 1000 1250 4
YGLR-63~1250A / I Type Fuse Group of Isolation Switch
It makes sure making and breaking circuit with load, with reliable over-current and short-circuit breaki ng prote ction, a lso obviously saw the breaking state.Own two poles, three poles, four poles ( three poles+ switch neutral pole). The fuser can be divided into 23 sp ecs from 63A to 1250A.

Structure and operation mode
■ Direct operation on front face: the handle is installed on the front face of switch.
■ Direct operation on side face: the handle is installed on the right of switch ( it is noted separately if the handle is installed on theleft of switch).
■ Front face operation outside of cabinet: the handle is installed on the front face outside of the distribution cabinet door.
■ Side face operation outside of cabinet: the handle is installed on the right of distribution cabinet outside. ( it is noted separately if the handle is installed on the left)
YGLR Series fuse group of isolation switch-2

YGLR-63~400A/I Outline and installation dimensions
YGLR Series fuse group of isolation switch-3
Specification Size of fuse External Dimension and Installation Dimension
A B D E F H H1 I J K L M P R T ΦX Y
YGLR -63A/3 0~00C 152 118 20~30 117


159 145 106 5 62.5 32



YGLR -63A/4 0~00C 184 118 20~30 117


159 145 106 5 62.5 32



YGLR -160/3 0~00 164 162 28~30 126 44 108 53 141 189 127 5.4 67 36 20 2.5 8.5 19.5
YGLR -160/4 0~00 200 162 28~30 126 44 144 53 141 189 127 5.4 67 36 20 2.5 8.5 19.5
YGLR -250/3 1 236 195 28~30 146 65 180 75 185 251 162 6.2 90.5 60 32 2.5 11 19.5
YGLR -250/4 1 296 195 28~30 146 65 240 75 185 251 162 6.2 90.5 60 32 2.5 11 19.5
YGLR -400/3 2 278 205 28~30 149 65 192 75 200 260 172 7 121 66 50 3 11 20
YGLR -400/4 2 344 205 28~30 149 65 258 75 200 260 172 7 121 66 50 3 11 20
YGLR Series fuse group of isolation switch-4
YGLR-400~630A/I Outline and installation dimensions
YGLR Series fuse group of isolation switch-5
Specification Size of fuse External Dimension and Installation Dimension







A A1 B B1 C E H H1 H2 J J2 J1 K M N P R S S1 T V U W ΦL Y
YGLR -400A/3 2 414 285 238 115 307 221 190 71 79 210 70 65 180 32.5 162 65 32 35 43 5 40.5 208 39.5 7 69
YGLR -400A/4 2 474 345 238 115 307 221 255 71 79 210 70 65 180 32.5 162 65 32 35 43 5 24.5 208 39.5 7 69
YGLR -630A/3 3 470 345 300 150 348 268 235 85 85 250 100 76 250 38.5 162 80 50 50 50 7 45.5 260 44.5 9 74
YGLR -630A/4 3 550 425 300 150 348 268 315 85 85 250 100 76 250 38.5 162 80 50 50 50 7 34.5 260 44.5 9 74
YGLR Series fuse group of isolation switch-6

Specification Size of fuse External Dimension and Installation Dimension







A A1 B B1 E H H1 H2 J J2 J1 K M N P R S S1 T V U W ΦL Y
YGLR -400A/3 2 500 285 238 115 221 190 71 79 210 70 65 180 32.5 119 65 32 35 43 5 40.5 208 39.5 7 69
YGLR -400A/4 2 560 345 238 115 221 255 71 79 210 70 65 180 32.5 119 65 32 35 43 5 24.5 208 39.5 7 69
YGLR -630A/3 3 550 345 300 150 268 235 85 85 250 100 76 250 38.5 119 80 50 50 50 7 45.5 260 44.5 9 74
YGLR -630A/4 3 630 425 300 150 268 315 85 85 250 100 76 250 38.5 119 80 50 50 50 7 34.5 260 44.5 9 74
YGLR-1250A Outline and installation dimensions
YGLR Series fuse group of isolation switch-8 YGLR Series fuse group of isolation switch-7

Home