Y-701 Dual-Automatic transfer switch controller

Place of Origin: Zhejiang China One Two Three Electric
Model number: Y-701
installation method: 分体式
display mode: indicator light
rated duty: uninterrupted duty
normal power detect: four-phase lacking phase detection,three-phase over-voltage/under-voltage detection.
standby power detect: four-phase lacking phase detection,three-phase over-voltage/under-voltage detection.

Quantity:
Introduction
Y-701/Y-702 series Dual- Automatic Transfer Switch Controller is an ideal ATS controller which equipped with Microprocessor Measuring unit,Programmable Output unit,Communication unit(only 702),Indicator Display(701 NORMAL,702 LED) function,adjustable Conversion Delay function,adjustable working models and Intelligent Power Module to reduce the risk of man-made operation.
Due to the core is made up of microprocessor,Y-701/Y-702 series controller can detects any tiny changes(over-voltage,under-voltage and lacking phase) of the circuit and output the passive switch quantity signal.

Operational environment
□ The ambient temperature should be higher than -10℃ and lower than 60℃.
□ the ambient altitude should not be higher than 2000m.
□ the ambient electrical pollution class should not be higher than level 3.
□ the ambient relative air humidity should not be higher than 50%,40℃,the ambient temperature should not be higher than 25℃ while in the wettest month(The average maximum humidity of the month should be lower than 90%).
□ If the environment is not up to the standard,the demand-side should notice the supply-side in advance.

Product Features
Y-701 series Dual-Automatic Transfer Switch Controller -1
Note: only the solid squares have the function

function introduction
□Self-input and self-restore.when the normal power was broke down(lacking phase,over-voltage or under-voltage),The ATS will connect up to the standby power until the grid back to normal.
□ Self-input but no self-restore.not same to the 1,the switch will keep connecting up to the standby power until manual operation.
□ Power port share to each other. Followed 2,now the power grid is right,and the switch is connecting up to standby power,till the standby power break down,the switch will turn back to the power grid.
□ Error alarm.when the ordered instruction can't be execute in the prescribed time,the controller will stop executing(outputting),and the Y-701's indicator light will start system checking(at same time the Y-702's indicator light shows dual flicker).press the"Manual/Auto" button to stop the alarm.
 
Setting mode of Y-701 controller
setting mode of self-input and self-restore,self-input but no self-restore,power port share to each other.
In the "Auto" mode,press both "A closing" and "B closing" buttons to start setting,then press "A switch on" to select the right mode.

Y-701 series Dual-Automatic Transfer Switch Controller -2
Setting mode of Y-702 controller
□ parameter setting
Press "Manual/Auto" button ten times to start setting.Press "A closing" or "B closing" to select.
□ parameter modify
After enter the above mentioned panel,press "Manual/Auto" button to start/cancel modifying (digit start to flash),press "A closing" to increase and press "B closing" to decrease.
□ save&exit setting
When the setting action completed,and the digit is still flashing,press "All OFF" button to save and exit(Only this way can save the modification).